Buy XS-3111 from Ascon in Paraguay

BRAND Ascon
Product XS-3111
Description Digital controller series XS (unconfigured)
Internal code IMP4489798
Technical specification Supply voltage: 100... 240V, 50/60 Hz Interface: serial Protocol: ASCII Auxiliary output Y4:4... 20mA or 0... 10V Version as program controller (1 program with 11 segments) inputs: - Pt100, thermocouple (J, L, K, S, R), - Standard signal 0 (4)... 20 mA or 0... (1) 10 V - 3 logic inputs Control output Y1: Relay, logic or continuous (4... 20 mA or 0... 10 V) Control behavior: - 2-point (heating or cooling) or - 3-point (heating/cooling, PID, PI, PD, P) Auxiliary output Y2, Y3: alarm relay - Can be configured as a deviation, band, limit or loop break alarm Dimensions: 96*48 mm (DIN), depth 150 mm Degree of protection: front IP54 default: - 24 V voltage output for ext. transmitter - Handheld device (manual manipulated variable presetting) - Auto-tune and expert tune - CE mark - Continuous output (setpoint or actual value, 4... 20 mA or 0... 10 V) - IP65 front protection

Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for Ascon - XS-3111 Digital controller series XS (unconfigured) number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in Paraguay Industrial products Market.

WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

More products of Ascon

CD3S10045480SSR

Type CD3000S-1PH 45A-480V SSR Einphasensteller circuit, zero crossing switch 45A load current (45A @ 40C 36A @ 50C) Load voltage to 480V Control logic (OFF <1.0 Vdc, ON 4 ... 30Vdc power type) 12mA 52x120x120mm dimensions (W) ideal for heating control with resistive load (zero crossing) antiparallel-connected thyristor CE mark save space by integr.Kuehlkoerper Rc-element and varistor integrated LED status display DIN rail mounting or screw fixing Tariff Num.8536 2010 ...

DY-0024

(Backlight+Lamp)

LAMP FILAMENT FOR AC-20 (OBSOLETE)

LAMP FILAMENT FOR ASCON CONTROLLER ( AC-20 )

M1-3000-0200

Temperaturregler

M3-3100-0200 (M3-3100-0200/9999)

temperature controller

M3-3100-0200/9999

Temperature Controller

M3-3100-0200

Temperature controller series M3 (unconfigured)

M3-3100-0200

Temperature controller series M3 (unconfigured)

M3-3100-0200/9999

Temperature controllers M3

M3-3100-0200/9999

(Temperature controller series M3 (unconfigured) G.Nr .: A.Nr .: Supply voltage: 85 ... 265 V ~ Output OP1 / 3: relay (2A / 250V contact) Output OP2: relay (2A / 250V contact) or logic (0 / 5VDC, 30mA) not galv. isolated adjustable via internal jumpers Output OP4: no Serial interface: no Interface protocol: no Transmitter supply: no Setpoint / Special Function: Without Manual: German / English Front color: dark gray can be configured as follows: Input: PT100; Thermocouple L, J, T, K, S; 0 (10) ... 50 mV DC, 0 (4) ... 20mA via shunt OP1 output: control or alarm output Output OP2: control or alarm output Output OP3: alarm output Output OP4: actual value or setpoint output (optional) Control: ON / OFF, or PID, heating or cooling Assignment: 1 output to the control unit and 1 output as an alarm o. both outputs as an alarm Options: current transformer input, transmitter supply, Analog Output (PV))

M3-5107-0200/9999 (M3-5107-0200)

Temperaturregler Serie M3 (unkonfig)

M4-5107-0000

Transmitterversorgung und Analog-Ausgang

M4-3107-0000

temperature controller

M4-3107-0200

thermostat

M4-3107-0200

thermostat

M4-3107-0200

Thermostat M4 Series (unkonfigueriert) Power supply 85 ... 265V Output OP1 / 3 relay (2A / 250V NO) OP2 output relay (2A / 250V NO) or logic (o / 5 VDC, 30 mA) is not electrically isolated. separately adjustable by internal jumpers OP4 output current output 0 (4) ... 20mA 750O hm / 15Vmax galv.getrennt / 500V / 1min Serial interface without Interface protocol without Transmitter supply (TV) 18 V konfiguiert be free can as follows: Input PT100, thermocouple L, J, T, K, S 0 (10) ... 50 mV DC, 0 (4) ... 20 mA via shunt Output OP1 rule or alarm output Output OP2 rule or alarm output Output OP4 control output 0/4 ... 20 mA Rmax 750R ON / OFF control or PID, heating or cules Assignment 1 output to the control unit and 1 output from alarm

M5-3100-1200

(Controller / program controller series M5-3100-1200 A-No .: G-No .: Front: 48 x 48 mm Supply voltage: 100 ... 240 V, 50/60 Hz Logic inputs: 2 Auxiliary input: no Output OP1: relay (2A / 250V contact) Output OP2: relay (2A / 250V contact) Output OP3: relay (2A / 250V contact) Serial interface: no Interface protocol: no Actual value OP4: no Front color: dark gray Setpoint program: up to 16 segments can be configured as follows: Input: PT100; Thermocouple J, L, T, K, S, R, T; 0 ... 50 mV DC 0 (1) .... 5 V DC; 0 .... 10V DC, 0 (4) ... 20 mA Control: ON / OFF, PID, heating or cooling, Heating / cooling, 3 pt step Options: ext. Setpoint, current transformer Entrance, continuous control output, or serial interface)

M5-3101-0200

.Regler Series M5-3101-0200 (unkonfiguriert)

M5-3101-0200

Rules, unkonfiguriert

M5-3101-0200

Rules Series M5-3101-0200 (unkonfiguriert)

M5-3151-0200

.regler

M9 MA

HEAT INDICATOR

Contact us for request