Buy 1-MVD2555 from Hbm in Paraguay

BRAND Hbm
Product 1-MVD2555
Description Measurement amplifier with integrated digital display
Internal code IMP4876441
Technical specification 4.8kHz carrier frequency, for DMS and inductive transducers for half and full bridge switching, piezoresistive sensors, as well as LVDTs, potentiometers - Output ± 10 V, ± 20 mA or 4-20 mA - 4 limits can be set - 2 peak value memories, functions: positive; negative; peak-to-peak - 10-digit alphanumeric LCD display with Backlight ±199.999 - 8 parameter memories - Low pass filter 0.05-1000 Hz - RS232 computer/printer interface for switchboard installation, 144 x 72 mm front frame 230 VAC, 48-60 Hz power supply

Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for Hbm - 1-MVD2555 Measurement amplifier with integrated digital display number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in Paraguay Industrial products Market.

WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

More products of Hbm

1-TB1A/5KNM

Reference torque measuring disc, nominal torque 5 kNm DMS measuring system Accuracy class: 0.05 Permanently mounted connection cable 3m, with free ends Torque transmission via flange Torque output signal 1.5mV / V

1-WA/100MM-T

displacement transducer

1-WS/ZB 12 ALTERNATIF

Mitutoyo Mark Magnetblock HBM can not be produced

1-Z6FC3/50KG-1

(load cell Rated load: 50kg Minimum division value: 0.0090% of Emax OIML R60 test report Accuracy: C3 Measuring body: Stainless steel Protection: IP68 according to EN 60529 Cable: Shielded 6-wire round cable with PVC Cable length: 3m)

3-3312.0182

SUB-D-Stecker

C2/50KN

compressive force transducer

D-MONT

Anschlussstecker

DQ809

8-channel USB measurement amplifier espressoDAQFamilie

D-TEDS/MONT-DB

including programming the memory contents of the TEDS TEDS Aufnehmersteck module is mounted.

HLC-40KN

Type HLM-20242 Output 1.8 millivolts load cell

HLCB1C3 1,1

Emax: 2.2 t, Emin: 0 kg, Limit: 3.3 t Vmin: 220 g, Cn; 1.94 mv/v; TC2163

HLCB1C3/4.4T

Load cell

KAB0104-10

cable and connector set. This product contains HK31S-G and 10 m of cable wiring.

K-CAL-F-D-7-B-S-S

(Calibration of the measured variable force in accordance with the HBM standard (without connector assembly). Traceability by DAkkS accreditation guaranteed by ISO 17025 or at factory calibrations (WCS) in Reference to ISO 10012 Calibration certificate in German and English Calibration type force DAkkS ISO 376, 8 steps Calibration power <= 1 MN Of load power tension and compression Number of measuring bridges Power Easy Bridge TEDS TEDS programming without programming)

K-CAL-T-W-1-B-S-S-2-0

Calibration of the measured variable torque according HBM standard (Without connector or coupling assembly. Traceability through accreditation ISO 17025 (DKD) guarantees In DAkkS / DKD - calibrations optionally by: DIN 51309, EURAMET / cg-14, VDI2646 (Teilbereichskal. Not possible) DKD-R 3-5 (turning moment), or DKD-R 3-7 (transfer torque wrench). Factory calibrations (WCS) in relation to ISO 10012th Calibration certificate in German and English Calibration type torque WKS, 6 steps, 1 + 1 measurements Measuring range <= 200Nm Load direction right and left Moment Number outputs an output signal TEDS TEDS programming without programming 1. Signal output mV / V 2. Signal output 0

K-CAL-T-W-5-B-S-S-2-0

Calibration of the measured variable torque according HBM standard (Without connector or coupling assembly. Traceability through accreditation ISO 17025 (DKD) guarantees In DAkkS / DKD - calibrations optionally by: DIN 51309, EURAMET / cg-14, VDI2646 (Teilbereichskal. Not possible) DKD-R 3-5 (turning moment), or DKD-R 3-7 (transfer torque wrench). Factory calibrations (WCS) in Terms of ISO 10,012th Calibration certificate in German and English Calibration type torque WKS, 6 steps, 1 + 1 measurements Measuring range <= 10kNm Load direction right and left Moment Number outputs an output signal TEDS TEDS programming without programming 1. Signal output mV / V

K-LY43-3/120-3-7.5M

technology özllkler ksmnda blgi was

K-P3-MB-200B-Y  

Absolute Pressure Measuring system: strain gauge 350 Ohm

K-RTN-S-C3-150-N-12-N-N-S-S

(K-RTNaa / bbb cccc dd eee Compact RTN load cell as a variant in special design DMS-measuring system (4000 ohms), nominal characteristic value 2.85 mV / V, with fixed cable, free ends, IP68 protection to EN 60,529th design standard Accuracy class C3 Rated load 150t Explosion protection No explosion Cable length 12m Others without TK0 without Country / customer default Creep 20 ° C Standard)

K-RY81-1,5/350

3-way rosette 1.5, 350 OHM LUK / SENSOR / 3Set floors form

K-U15-250K-SB-S-U-B-J

(K-U15 Force transducers for tensile and compression forces Class 0.5 to ISO 376 Class only guaranteed with the optionally available DKD calibration DMS-measuring system 350 Ohm Nominal sensitivity of 2 mV / V (2.5 kN ... 10 kN) Nominal characteristic value 3 mV / V (25 kN 1 ... MN) Nominal force 250kN Measuring bridge number Simple bridge Transducer identification TEDS without Inlet Protection without plug Protection Mating guide bridge A bayonet connector Parameter adjusted)

MP85ADP

Process Controller

MX840A

8-channel universal amplifier of QuantumX family

Contact us for request