BRAND | Ascon |
Product | K43PROH001--0AT |
Description | Control system 4.3p panel * KRD50HCRRRDSE * Horizontal AT logo |
Internal code | ONR4308194 |
Please Contact Us to Order to offer competitive prices and delivery time for Ascon - K43PROH001--0AT Control system 4.3p panel * KRD50HCRRRDSE * Horizontal AT logo number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in Paraguay Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
(Temperature controller series M3 (unconfigured) G.Nr .: A.Nr .: Supply voltage: 85 ... 265 V ~ Output OP1 / 3: relay (2A / 250V contact) Output OP2: relay (2A / 250V contact) or logic (0 / 5VDC, 30mA) not galv. isolated adjustable via internal jumpers Output OP4: no Serial interface: no Interface protocol: no Transmitter supply: no Setpoint / Special Function: Without Manual: German / English Front color: dark gray can be configured as follows: Input: PT100; Thermocouple L, J, T, K, S; 0 (10) ... 50 mV DC, 0 (4) ... 20mA via shunt OP1 output: control or alarm output Output OP2: control or alarm output Output OP3: alarm output Output OP4: actual value or setpoint output (optional) Control: ON / OFF, or PID, heating or cooling Assignment: 1 output to the control unit and 1 output as an alarm o. both outputs as an alarm Options: current transformer input, transmitter supply, Analog Output (PV))
M3-5107-0200/9999 (M3-5107-0200)
Temperaturregler Serie M3 (unkonfig)
Transmitterversorgung und Analog-Ausgang
temperature controller
thermostat
(Controller / program controller series M5-3100-1200 A-No .: G-No .: Front: 48 x 48 mm Supply voltage: 100 ... 240 V, 50/60 Hz Logic inputs: 2 Auxiliary input: no Output OP1: relay (2A / 250V contact) Output OP2: relay (2A / 250V contact) Output OP3: relay (2A / 250V contact) Serial interface: no Interface protocol: no Actual value OP4: no Front color: dark gray Setpoint program: up to 16 segments can be configured as follows: Input: PT100; Thermocouple J, L, T, K, S, R, T; 0 ... 50 mV DC 0 (1) .... 5 V DC; 0 .... 10V DC, 0 (4) ... 20 mA Control: ON / OFF, PID, heating or cooling, Heating / cooling, 3 pt step Options: ext. Setpoint, current transformer Entrance, continuous control output, or serial interface)
.Regler Series M5-3101-0200 (unkonfiguriert)
Policy
.regler
HEAT INDICATOR
M9-3151-0000 price valid only in 6-pack
user manual in English only (Gewicht 250g)
M9-3151-0000/AHL OEM/Kundenspezifisch
regulator Type: M9-3151-0000 / AHL Case dimensions: 48 x 48 mm Power supply: 100 ... 240V AC with 2 relay outputs Serial interface RS485 + IPOT
Policy
MS-30/30 ABA(replaced by MS-32/.9999)
Configuration 99/99 Power supply 100/240V
(Digital Controls MS (series unconfigured) - Power supply voltage: 100 ... 240V, 50/60 Hz - Serial interface: 2-wire TTY, ASCII optinoal - Dimensions: 48 x 48 mm DIN, depth 110 mm - Weight approx 200 g - input (configurable): * Pt100 * Thermocouple (L, J, K, S) * Standard signal 0 (4) ... 20 mA or 0 ... 1 (10) V Exit: * Main output Y1: relay or logic * Auxiliary output Y2: Alarm relay - PID control with self-optimization and setpoint ramp - heating or cooling characteristic with alarm output or Heating / cooling characteristic without alarm output configurable - Simultaneous display of set and actual values - control output configurable as relays or logic signal - ramp function - Power limitation - scalable inputs for standard signals - configuration via front keys - Voltage output for external 24 V - Transmitter - Parameter lock - Front protection: IP 54, with transparent cover IP 65 (optional) - Customs number: 9032/1020)
Digital controller
Digitalregler der Serie MS