For years, Onrion LLC has been your trusted supplier of Inor products in the Paraguay . We offer a vast selection of Inor tools and accessories at competitive prices, ensuring timely delivery across the UK.
Visit our website to explore our extensive catalog of Inor products. If you do not find the specific product you are looking for, please do not hesitate to contact us. Our knowledgeable team is dedicated to helping you find the perfect solution to meet your industrial needs.
Thanks to our comprehensive distribution network, we guarantee that your orders will be delivered promptly, no matter where you are located in the Paraguay . Our commitment to exceptional customer service means we are here to support you every step of the way.
Important Notice: While we supply Inor products, Onrion LLC is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
gem (alarm unit (19 ... 60 V DC) for DIN rail mounting. EN 50022, 35 mm for Pt100 input; 4 ... 20 mA output; Supply voltage: 19 ... 60 V DC Weight: about 200 g)
gem (2-channel alarm unit (19 ... 60 V DC) for DIN rail mounting. EN 50022, 35 mm; for mA / V signals; 4 ... 20 mA output; Supply voltage: 19 ... 60 V DC; Weight: about 200 g)
sensor
Analog Adjustable 2-wire Transmitter
for T / C J, L, T, K, N; (Analog DIN rail transmitter; not separated electrically. Span: 10 ... 50 mV Continual, fine adjustment:. ± 10%; Zero point: ± 10% of span; Output: 4-20 mA, voltage-linear; Type. Accuracy: ± 0.5 ... ± 1.0% of span; Adjustable via solder bridges and potentiometers; Default: without calibration; Weight: g 40)
Pt100 3W-50/+50C
(Analog, PC-programmable, electrically. Uninsulated two-wire transmitter for Connection head assembly DIN B or greater; Pt100 input in 3-wire connection; linear with temperature; Minimum span 20 ° C; Zero adjustment: -50, -25, 0, 25, 50 ° C; Output: 4-20 mA; Default: Pt100; 3L .; 0 ... 100 ° C; Weight: 40 G)
Configuration
optional: 70CAL00002 Factory calibration/adjustment of transmitter types: APAQ
PC programmable four-wire DIN rail mount transmitter
PC-programmable two-wire transmitter for connection head assembly DIN B or greater; Galvanic isolation 1.5 kV; Input Pt100 ... Pt1000; 3- or 4-wire connection; Ni100 ... Ni1000; 11 T / C; Output: 4-20 / 20-4 mA; linear with temperature; Default: Pt100; 3L .; 0 ... 600 ° C; Weight: 40 g
PC-programmable two-wire transmitter for connection head assembly DIN B or greater;
PC programmable two-wire transmitter for DIN rail mounting;Inp. / Outp. galvanically isolated 1,5 kV, 11 T / C, Pt100 ... Pt1000; Ni100/Ni1000, 3 -or 4-wire connection; 4-20/20-4 mA output, linear with temperature;Factory setting: Pt100, 3L, 0 ... 600 ° C, weight: approx. 40gIncluding: 70CAL00001 - Programming / Configuration:Pt100, 4-wire connection; -20 ... +160 ° C, 4 ... 20 mA
PC-programmable two-wire transmitter for DIN rail mounting
The temperature transimitter
70APLC0001 APAQ-LC Analog Adjustable Two-Wire Transmitter for thermocouple input and 4... 20 mA output DIN Rail Mounting uncalibrated
PC-programmierbarer Zweidraht-
ORDER: 49,499,237. 3-L; -20..100 DEGREES
Vishay Displacement transducer Input voltage 3Vrms Linear range: 0- 100mm
(THERMOMETER *** Only Thermowell *** Type: *** OPTITEMP TCA-P 62 Special ***, Protection Tube: 1.4762 Chrome Steel - diameter: Æ 22x2,0 mm - tip design: Straight tip design Process connection: Compression Fitting G1"; 1.4404 (300 °C) Acessories: *** Stop ring ***, APPLICATION DATA Immersion Length: 1200 mm Extension Tube: 0 mm STC1920ABA3530Z0000000000000)
(THERMOMETER *** Only Thermowell *** Type: *** OPTITEMP TCA-P 62 Special ***, Protection Tube: 1.4762 Chrome Steel - diameter: Æ 22x2,0 mm - tip design: Straight tip design Process connection: Compression Fitting G1"; 1.4404 (300 °C) Acessories: *** Stop ring ***, APPLICATION DATA Immersion Length: 1020 mm Extension Tube: 0 mm STC1920ABA3530Z0000000000000)
(Connection head: AA, aluminium; Cable gland M20x1,5; Protection class IP54 Measuring insert: Mii, replaceable, spring-loaded;1x Type K (NiCr-Ni); Sensor cass 1, Temp. range type K max 1150 °C; Inconel 600 Protection tube: 1.4762 Chrome Steel - diameter: Æ 22x2,0 mm - tip design: Straight tip design Process connection: Compression Fitting G1"; 14404(300 °C) Acessories: *** Stop ring *** Immersion Length: See Application Data Connection head mount transmitter; two-wire universal transmitter - type: TT30C / - design: head mounted / - input: RTD/Thermocouple - galvanical separation: 1500 VAC, 1 min Private Label: KROHNE Standard Version,APPLICATION DATA Immersion Length: 1200 mm Extension Tube: 0 mm STC1920ABA3530Z0701000000000)
(THERMOMETER Plug-In Thermocouple Type: ''' OPTITEMP TCA-P 62 Special ***, Connection head: AA, aluminium; Cable gland M20x1,5; Protection class IP54 Measuring insert: Mii, replaceable, spring-loaded;1x Type K (NiCr-Ni); Sensor cass 1, Temp. range type K max 1150 °C; Inconel 600 Protection tube: 1.4762 Chrome Steel - diameter: Æ 22x2,0 mm - tip design: Straight tip design Process connection: Compression Fitting G1"; 14404(300 °C) Acessories: *** Stop ring *** Immersion Length: See Application Data Connection head mount transmitter; two-wire universal transmitter - type: TT30C / - design: head mounted / - input: RTD/Thermocouple - galvanical separation: 1500 VAC, 1 min Private Label: KROHNE Standard Version, APPLICATION DATA Immersion Length: 1020 mm Extension Tube: 0 mm STC1920ABA3530Z0701000000000)
Isolationssignal-Splitter mit doppelten Ausgängen für mA/V Signale