BRAND | Stahl |
Product | 158905 / 9002/77-093-040-001 |
Description | Safety Barrier |
Internal code | ONR4607612 |
Custom code | 90328900 |
Discover the superior quality and performance of the Stahl 158905 / 9002/77-093-040-001 with Onrion LLC in Paraguay . Whether you are looking for reliability or efficiency, this product meets all your industrial needs.
The 158905 / 9002/77-093-040-001 is designed to provide optimal performance and durability in various applications. Known for its high-quality construction and innovative features, it is a preferred choice for professionals.
Key Features of 158905 / 9002/77-093-040-001 :
At Onrion LLC , we offer the 158905 / 9002/77-093-040-001 at competitive prices and with the fastest delivery times across Paraguay . Our expert team is ready to assist you with all your inquiries and provide tailored solutions to meet your specific needs.
Why Choose Onrion LLC ?
Get Your Quote Today! Ready to enhance your operations with the 158905 / 9002/77-093-040-001 ? Contact us now for a personalized quote. Fill out the form below or send us an email with your inquiry. Let us help you make a cost-effective, quality-driven choice for your business.
Important Notice: While we supply Stahl products, Onrion LLC is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
IS PAC Isolating Repeater Switching Repeater Field Circuit Ex i explosion-protected Type : 9170/10-12-21s Max. Voltage Uo : 10,6 V Max. Current Io : 24 mA Max. Demand Po : 64 mW Min. nominal voltage : 120 V Max. nominal voltage : 230 V Nominal current : 12 mA Number of channels : 1 Output / channel : 1 change over contact LFD relay : Yes Line fault transparency : No Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C Dust explosion protection : II (1) D [Ex ia] IIIC For further information, see : www.r-stahl.com Web code 9170A Switching Repeater Series 9170, Field Circuit Ex i, single channel Basic function: binary / digital input Intrinsically safe input: [Ex ia] IIC Power supply: 120 ... 230 V AC Input: acc. to EN 60947-5-6 (NAMUR) Output / channel: 1 change-over contact Connection type: Screw terminals
(Emergency Strip light for fluorescent lamps Type: 6608 / 5.2-9 ...-... 7 Specifications: Gas explosion: II 3 G Ex nAC II T4 dust explosion protection: II 2 DT 80 ° C test certificate: DMT 03 E 093 / ATEX e 094 x Suitable for: fluorescent lamp 2Stift, 2 x 18W reflector embodiment: symmetric wide distribution material: polyester resin surface: No coloring IP 66 ambient temperature: -20 ° C ... 40 ° C voltage: 220 V -10%. .. 254 V + 10%; 50/60 Hz cable entry: 2 x cable entry M25x1,5 1 x sealing plug M25x1,5 without bulb through wiring conductors 6 shutdown when opening the luminaire (mains voltage and battery circuit) with duration test)
Repair kit 2x36W QTP8 Ers.QTIS-B Electronic Ballast + Accessories
Repair kit 2x18W QTP8 QTISElektronisches Ers. Ballast + Accessories
Control Pendant selection STH 6102-009
Switch socket 3P+N+PE 63A, 200/346-240/415V, 50+60Hz, red CCT No.: 85366990 DE Net weigth: 7,800 KG
Switch socket explosion-protected
201404 8146/5-V37-302-50-0050 SPARE OF TYPE : 8537/2-302-7000; 8537/2-702-7000
(Safety Switches 16 A explosion-protected Rated operational voltage AC : 400 V Rated operational current : 16 A Enclosure material : Polyester resin glass fibre-reinforced Detailed number of poles : 3 P Auxiliary contact NC : without Auxiliary contact NO : 1 NO lagging Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex de IIC T6 Gb Dust explosion protection : II 2 D Ex tb IIIC 80 °C Db Min. ambient temperature : -40 °C Max. ambient temperature : +51 °C Special conditions for extended ambient temperature, see operating instructions: Extended min. ambient temp. : -40 °C Extended max. ambient temp. : +69 °C Type of protection (IP) : IP66 Colour of handle : standard black Cable gland : 2 x M25 Ø 7 ... 17 mm 1 x M20 Ø 6 ... 13 mm Connection cross-section : 2,5 ... 6 mm2 Connection cross-section aux.: 1,5 ... 4 mm2 finely-stranded 1,5 ... 6 mm2 solid CCT No.: 85365080 DE Net weigth: 1,590 KG)
6141/61-16 Hand lamp with LED Hand Lamp Series 6141/6, explosion protected Rated data: 3 V Batteries: Hand lamps are supplied with batteries. For other battery types see operating instructions For use in: Zones 1 & 2, 21 & 22
Fibre optic top piece
Belt bag
YO3/ISC/T4 ATX YO3 Hupe Ex i ATEX, T4
YO5/ISC/T6 ATX YO5 Hupe Ex i ATEX, T6
MCP / PB / SP / Ex / A + B + C + D / EU / R / LED / D / T push-button manual call, 12-50VDC /
Batterie 6148 6V 4,5Ah replacement set
Diffusing lens clear accessories
Command and Meldegeraet
Lighting with 1-pin 1x18/20W
18W EXPROOF
Light fitting for fluorescent lamps explosion -protected
(2*36)
Flooding Series 6121,explosion protected;Version Size 3; 6121 /53 ; Lamps: HIT/HST=Metal halide lamps/High-pressure sodium lamps;Note:the light fittings are supplied without lamps.Lamp holder E40;Lamp wattage 400W; Cmpensation without Light aperture broad bowl;For use in : Zones 1 and 2 , 21 and 22;
main lamp, halogen lamp, 4.0 V; 2W, order number 119848